RX-515 Gas MonitorThe LNG Carrier model is a combination type portable CH4, O2, CO and CO2 gas detector with an Infrared (NDIR) type sensor, galvanic cell type sensor and Electro-chemical cell type sensor. These sensors provide accurate detection of CH4, O2, CO and CO2 levels even in N2 and other inert environemnts. The measuring ranges are 0-100%LEL / 0-100%vol for CH4, 0-25%vol for O2, 0-1000ppm for CO and 0-20.0%vol for CO2 respectively. The RX-515 has an explosion proof and Intrinsically Safe design so that it can be used safely in any environment.

Features

  • Dual range detection of CH4 or HC in %vol and %LEL.
  • Unique gas combinations include: CH4/O2/CO/CO2/HC/O2/H2S
  • Accurately measure CH4 or HC from inerted tanks with infrared sensor.
  • High range H2S 0-1,000ppm available (RX-517).
  • Intrinsically safe design.
  • Datalogging (Max 30 hours of interval trend).

Application

  • LNG Carrier Storage Vessel gas monitoring

Specifications

RX-515
Gas Detected
Methane (CH4)
Oxygen (O2)
CO
CO2
Detection Principle NDIR Galvanic cell Electro-chemical cell
NDIR
Detection Range (digit) 0~100%LEL
(0.5%LEL)
5-100%vol (0.5%vol)
0-25 vol% (0.1%vol) 0-1000 ppm
(1ppm)
0-20.0%vol
0-2%vol (.01%)
2-5%vol (.05%)
5-20%vol (.1%)
Operating Temp. & Humidity
-10°C ~ + 50°C (14 to 122°F),
below 90%RH, non-condensing
Safety Rating
Exiad II BT3X (Alkaline batteries "Size C" only), KIMM approved, MED approved, with "Wheel mark"
(Certificate No. 15520/A0EC)
Power Source 4 “C” Alkaline dry cell batteries
Continuous Operation Approx. 30 hours (no alarm or light, at 25ºC)
Display Digital LCD (with back light)
Alarm Types
    Gas Alarms: Standard ...OFF
    (optional ..1st and 2nd user adjustable, self-resetting)

    Trouble Alarms (self diagnosis): Sensor connection, low battery, circuit trouble and calibration error
Dimensions & Weight Approx. 80 (H) x 200 (W) x 142 (D) mm (3.1” H x 7.9” W x 5.6" D), approx. 1.8 kg (4 lbs)
Special Functions
Peak hold, Datalogging
Standard Accessories
    Carrying case with shoulder strap
    Filter tube with flow monitor and junction tube
    Gas sampling hose
    Gas sampling probe
    Alkaline battery (4 "C" size)
    CO2 scrubber
    Instruction manual

Specifications subject to change without notice. 

Crude Oil Tanker Storage Tank Gas Monitor

DatasheetManual

RX-515 Gas MonitorThe Crude Oil Tanker model is a combination type portable HC, O2, and H2s gas detector with an Infrared (NDIR) type sensor, galvanic cell type sensor and Electro-chemical cell type sensor. These sensors provide accurate detection of HC, O2 and H2S levels even in N2 and other inert environments. The measuring ranges of model RX-516 are 0-100%LEL / 0-10%vol for HC, 0-25% vol for O2 and 0-100.0ppm for H2S respectively. A higher range for H2S (0-1,000ppm) is available in model RX-517. A manual switch is used to change the flow to a unique path for high H2S applications to protect the other sensors. The RX-516 / RX-517 has an explosion proof and Intrinsically Safe design so that it can be used safely in any envrionment.

Features

  • Dual range detection of CH4 or HC in %vol and %LEL.
  • Unique gas combinations include: CH4/O2/CO/CO2/HC/O2/H2S
  • Accurately measure CH4 or HC from inerted tanks with infrared sensor.
  • High range H2S 0-1,000ppm available (RX-517).
  • Intrinsically safe design.
  • Datalogging (Max 30 hours of interval trend).

Application

  • Crude oil tanker storage tank gas monitoring

Specifications

RX-516 & RX-517
Gas Detected
Iso-butane (HC)
Oxygen (O2)
H2S
Detection Principle NDIR (Non-Dispersive infrared) Galvanic cell Electro-chemical cell
Detection Range (Increments) 0~100%LEL
(0.5%LEL)
2-100%vol (0.5%vol)
0-25 vol% (0.1%vol) <LOW>
0-100 ppm (.5ppm)
<HIGH>
0-1,000 ppm (1ppm)
RX-517
Operating Temp. & Humidity
-10°C ~ + 50°C (14 to 122°F),
below 90%RH, non-condensing
Safety Rating
Exiad II BT3X (Alkaline batteries "Size C" only), KIMM approved, MED approved, with "Wheel mark"
(Certificate No. 15520/A0EC)
Power Source 4 “C” Alkaline dry cell batteries
Continuous Operation Approx. 30 hours (no alarm or light, at 25ºC)
Display Digital LCD (with back light)
Alarm Types
    Gas Alarms: Standard ...OFF
    (optional ..1st and 2nd user adjustable, self-resetting)
    Trouble Alarms (self diagnosis): Sensor connection, low battery, circuit trouble and calibration error
Dimensions & Weight Approx. 80 (H) x 200 (W) x 142 (D) mm (3.1” H x 7.9” W x 5.6" D), approx. 1.8 kg (4 lbs)
Special Functions
    Filter tube with flow monitor
    Connection tube (green)
    Spiral sampling tube
    Gas sampling probe
    Carrying case with shoulder strap
    Alkaline battery (4 "C" size)
    Operation manual
Standard Accessories
    Filter tube with flow monitor
    Connection tube (green)
    Spiral sampling tube
    Gas sampling probe
    Carrying case with shoulder strap
    Alkaline battery (4 "C" size)
    Operation manual Sampling tube (30M)
    Gas sampling bag
    Ni-Cad battery charger

Specifications subject to change without notice. 