Gas Detection For Life

Leading gas detector manufacturer

 

RKI banner
Eagle 2 Calibration Station, SDM-E2

Stand Alone Calibration Station

SM2000 calibration station The SDM-E2 is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand-alone device for charging, calibration and bump testing, with all records automatically stored for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi Module System
The SDM-E2 can also be connected to a PC for automated calibration bump testing and archiving of datalog data from Eagle 2 instruments. Up to ten SDM-E2 docking stations can be connected simultaneously using USB cables. The SDM-E2 is also equipped with two gas ports to connect up to two calibration gas mixtures to the multi module system.

  • Features
  • Specifications
  • Ordering Info
  • Download

Features

 

Stand Alone Station

  • Stand-alone station (no connection to PC Required)
  • Charging (NiMH batteries)
  • Calibration
  • Bump Test
  • Save bump test and calibration records
  • Bump test and calibration records copy to USB jump drive
  • 2 Calibration gas ports
  • Includes PC software for viewing/archiving bump test and calibration records

Multi Module System

  • Multiple modules connected to a PC (10 max)
  • Charging
  • Calibration
  • Bump Test
  • Configure Eagle 2 parameters
  • 2 Calibration gas ports


EAGLE 2 gas meters

  • Archive Bump Test and Calibration records
  • Archive data to network location
  • Software controlled data retrieval
  • Automatic calibration/bump test option
  • Windows 7 compatible



 
Specifications subject to change without notice. 

Input Power

AC Adapter with 100 - 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard.

Environmental Conditions

• For Indoor Use Only

• -10° C to 40° C, below 80% relative humidity, non condensing

Applicable Instrument

Eagle 2

Maximum Number of Records Saved

200

Calibration Gas Ports

Connect up to 2 calibration gas cylinders to each station

Standard Accessories

• AC adapter

• USB flash drive

• Single module data viewer software

• SDM Docking station PC
controller software

• Inlet air filter

• Instrument manual

• 10’ exhaust tube

 
Specifications subject to change without notice. 

Ordering Information

The SDM-E2 can be ordered using the part numbers from the list below.

Docking Station*

81-SDME2-01

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing & installation CD

81-SDME2-02

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator

81-SDME2-03

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, fla sh drive, USB cable, tubing, installationtion CD, demand flow regulator, & 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2

81-SDME2-08-P1

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm isobutylene in Air

81-SDME2-08-P2

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 100 ppm isobutylene in Air

*Bold features indicate differences between the various versions of the docking stations.

Calibration Gases & Regulators

33-6010RK-04

CO2 scrubber (required for 0-10,000 ppm or 0-5% CO2 sensors)

81-0002RK-03

Cylinder, H2, 50% LEL in Air, 103L

81-0013RK-05

Cylinder, Methane, 50% volume in N2, 58L steel

81-0071RK-03

Cylinder, CO2, 5000 ppm in N2, 103L

81-0072RK-03

Cylinder, CO2, 2.5% in N2, 103L

81-0073RK-03

Cylinder, CO2, 15% in N2, 103L

81-0078RK-03

Cylinder, N2 100%, 103L

81-0089RK-03

Cylinder, CO 50 ppm / Hexane 15% LEL / O2 12 % in N2, 103L

81-0090RK-03

Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 103L

81-0103RK-03

Cylinder, Isobutylene 100 ppm in Air, 103L

81-0104RK-03

Cylinder, Isobutylene 10 ppm in Air, 103L

81-0142RK-02

Cylinder, SO2 5 PPM / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL

81-0142RK-04

Cylinder, SO2 5 PPM / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 34AL

81-0151RK-02

Cylinder, H2S 25 ppm in N2, 58AL

81-0154RK-02

Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL

81-0155RK-02

Cylinder, H2S 25 ppm / CO 50 ppm / HEX 15% LEL / O2 12% in N2, 58AL

81-0170RK-04

Cylinder, SO2 5 ppm in N2, 34AL

81-1054RK

Regulator, demand flow for 34AL/58AL/103L

Specifications subject to change without notice. 

Introduction | Description | Operation
Calibration | Maintenance | Setup Mode | PID Sensor


This video is also available on Youtube and CD (by request)

EAGLE 2 PID Response Factors for VOCs

Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC.

Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration.

spacer spacer spacer spacer

Gas / VOC

CAS No.

Formula

Relative
Response

 

SDM-E2