Model 1017 Fixed Gas Detector - RKI Instruments

Model 1017 Gas Detector

Model 1017

Explosion Proof Sample Draw LEL Sensor

Features

  • Monitors 0-100% LEL
  • Sample-draw with long life internal pump
  • Cast aluminum alloy housing
  • Stainless steel inlet and outlet fittings with flame arrestors
  • Housing and flame arrestors CSA and UL classified for use in hazardous locations Class I, Division I, Groups B, C, & D.
  • Also available for oxygen monitoring, 0-25% volume
  • Operates on 24VDC input
Contact Sales

Overview

The Model 1017 series is a compact sample draw direct connect LEL sensor assembly with a built-in pump that accepts a 24VDC input. This unit features a watertight cast aluminum alloy housing which is rated as explosion proof for Class I, Division I, Groups B, C, & D. The Model 1017 has a detection range of 0-100% LEL and can draw a sample from 100 feet away.

The Model 1017 can interface to any RKI Beacon 110, 200, 410, or M2 controllers, Beacon 800, Riken Kieki, or third party control system utilizing optional amplifier with 4-20 mA feedback signal. The stainless steel inlet and exhaust fittings on the bottom of the housing allow the gas sample to enter and exit. This is a very cost effective way of monitoring LEL with a sample draw direct connect sensor.

Related Services

Fixed Systems Turnkey Solutions

  • Design, Consultations, and Engineering
  • Installation
  • Start-up
  • Training
  • System Maintenance

 

Application

  • Gas Fired Electrical Generation Plants
  • Refineries
  • Water & Wastewater Treatment Plants
  • Manufacturing Facilities

Specifications

Target Gas

Combustible gas, methane calibration standard (oxygen detection version also available)

Input Power

24 VDC

Construction (housing)

Cast aluminum alloy, watertight, explosion proof, NEMA 4, 7, 9

Housing Approval

CSA and UL classified for use in hazardous locations Class I, Division I, Groups B, C, & D.

Location

Indoor or outdoor use

Temperature

32 to 104° F (0 to 40 C)

Dimensions

7.00 in. H x 7.00 in.W x 6.13 in. D

Sampling Method

Sample draw pump

Recommended Sample Flow

1.0 LPM

Detection Range

0 to 100% LEL, (optionally 0-25% volume oxygen)

Response Time

90% in 30 seconds

Accuracy

±5% of reading or ± 2% LEL (whichever is greater)

Warranty

One year material and workmanship

* Specifications subject to change without notice.
Made in USA.